The clean water distribution system for the Krembangan Pump House has a fairly large drainage area. This study aims to determine the existing conditions and conditions of network development in terms of water availability and demand, hydraulic conditions and water quality, and conditions of fire extinguishing wells in the network with a simulation of the WaterCad v8i. From the analysis result, the existing condition's network condition shows a deficit between water demand and availability of 149 l/s. Hydraulic conditions during peak hours of use, parameters 100% pressure, speed, and headloss gradient 74.1% do not become eligible. Residual chlorine does not qualify. The condition of the network development was improved by adding pipes to be parallel and adding one pump. The development conditions were simulated with three different conditions: reducing the water demand standard, rotating the water flow, and reducing the service area. The simulation results, the average pressure is between 0.8-10 atm. velocity 0.3-6 m/s, and a headloss gradient of 0-15 m/km. The sumur pemadam kebakaran (SPMK) simulation showed that the water did not fill the average well again at 09.00 - 16.00.
Sistem distribusi air bersih zona Rumah Pompa Krembangan memiliki daerah pengaliran yang cukup luas. Penelitian ini bertujuan untuk mengetahui kondisi eksisting dan kondisi pengembangan jaringan dari sisi ketersedian serta kebutuhan air, kondisi hidraulik serta kualitas air, dan kondisi sumur pemadam kebakaran pada jaringan dengan simulasi program WaterCadv8i. Kondisi jaringan pada kondisi eksisting terdapat defisit antara kebutuhan dan ketersediaan air sebesar 149 l/s. Kondisi hidraulik saat jam pemakaian puncak, parameter tekanan 100%, kecepatan, dan headloss gradient 74,1% tidak memenuhi syarat. Kualitas air masih belum terpenuhi syarat sisa klorin pada jaringan. Kondisi pengembangan jaringan diperbaiki dengan merubah 50 pipa menjadi paralel dan menambah satu buah pompa. Kondisi pengembangan dilakukan simulasi dengan tiga kondisi yaitu mengurangi standar kebutuhan air, melakukan penggiliran pengaliran air, dan mengurangi daerah pelayanan. Hasil simulasi, rata-rata tekanan berada diantara 0,8-10 atm. kecepatan 0,3-6 m/s, dan headloss gradient 0-15 m/km. SPMK, dilakukan simulasi, hasilnya menunjukan rata-rata sumur tidak terisi penuh kembali pada pukul 09.00 - 16.00.
References
J.S. Fidari, R.D. Lufira, E. Purwati, R. Haribowo., “Evaluation and Development of Network Distribution of Clean Water PDAM Unit Lawangâ€, The 7th Annual Basic Science International Conference (BaSIC 2017) 1, 194
Bentley Methods. 2007. User’s Guide WaterCAD v8i for Windows WATERBUY CT. USA: Bentley Press.
E.W. Diana, M. Solichin, R. Haribowo., “A study of clean water distribution network development at PDAM Tirta Barito in the city of Buntokâ€, IOP Conference Series: Earth and Environmental Science 437 (1), 012002
Badan Pusat Statistik. 2015. Pedoman Perhitungan Proyeksi Penduduk dan Angkatan Kerja. Jakarta: Badan Pusar Statistik.
Dayan, Anton. 1980. Pengantar Metode Statistik Jilid Satu. Jakarta: LP3ES.
Priyantoro, Dwi. 1991. Hidraulika Saluran Tertutup. Malang: Jurusan Pengairan Fakultas Teknik Universitas Brawijaya.
Effendi, H., Telaah Kualitas Air, Bagi Pengelolaan Sumberdaya dan Lingkungan Perairan. Yogyakarta: Kanisius, 2003.
Triatmadja, Radianta. 2013. Hidraulika Sistem Jaringan Perpipaan Air Minum. Yogyakarta: Beta Offset..
Triatmadja, Radianta. 2014. Teknik Penyediaan Air Minum Perpipaan. Yogyakarta: Beta Offset.
Keputusan Menteri Kesehatan Republik Indonesia. Nomor 416/Menkes/PER/IX/1990/1990. Syarat – Syarat dan Pengawasan Kualitas Air Bersih.
Kementrian Pekerjaan Umum. 2007. Penyelenggaraan Pengembangan Sistem Penyediaan Air Minum. Jakarta: Kementrian Pekerjaan Umum.
E. Rohmaningsig, M. Solichin, R. Haribowo., “Kajian Pengembangan Sistem Penyediaan Air Bersih Pada Daerah Rawan Air Di Desa Sumbersih Kecamatan Panggungrejo Kabupaten Blitarâ€, Jurnal Teknik Pengairan 8 (1), 48-59
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Jurnal Teknologi dan Rekayasa Sumber Daya Air

This work is licensed under a Creative Commons Attribution 4.0 International License.