Evaluasi Kualitas Air dan Sistem Hidran Pada Zona Pelayanan Betek Kota Malang Menggunakan Program WaterCAD
DOI:
https://doi.org/10.21776/ub.jtresda.2022.002.02.27Keywords:
Kualitas Air, Hidran, Klorin, WaterCADAbstract
The water need continues to be influenced by the rapidly growing population in an area, but this development is not accompanied by the availability of fresh water. PDAM (Municipal Water Supply Company) of Malang City consist of several Zones or DMA (District Meter Area), one of them is Betek Service Zone. the hydrant did not function properly, while the water quality was due to the Malang City hydrant being an integral part of the water distribution pipeline to the community. Evaluation of Water Quality and Hydrant System is based on the existing network condition in the Betek Service Zone where the Betek Reservoir water supply comes from the Tlogomas Reservoir from the Wendit Sources 1, 2 and 3. Betek Reservoir 1 flowing water by 101,189 liters/sec to DMA 1,2,4 and 5 and Betek Reservoir 2 of 233,339 liters/sec to DMA 3,6 and 7. Based on WaterCAD V8i software simulation in Betek Zone, the results of pressure, velocity, headloss gradient, and residual chlorine in existing and development conditions with the conditions of permitted pressure of 0.5-10 atm, permitted speed of 0.3-6 m/sec, permitted headloss gradient of 0-15 m/km and permitted residual chlorine of 0.3-0.5 mg/l.Kebutuhan air yang terus dipengaruhi oleh pertumbuhan jumlah penduduk yang semakin pesat disuatu daerah, Tetapi perkembangan tersebut tidak diiringi dengan penyediaan air bersih yang ada. PDAM (Perusahaan Daerah Air Minum) Kota Malang menjadi beberapa Zona atau DMA (District Meter Area) salah satunya Zona Pelayanan Betek. Hidran sekitar Kota Malang tidak berfungsi dengan baik adapun kualitas air dikarenakan hidran Kota Malang menjadi satu kesatuan dengan pipa jaringan distribusi air ke masyarakat. Evaluasi Kualitas Air dan Sistem Hidran didasarkan pada jaringan kondisi eksisting di Zona Pelayanan Betek dimana suplai air Reservoir Betek berasal dari Reservoir Tlogomas yang berasal dari Sumber Wendit 1, 2 dan 3. Reservoir 1 Betek yang mengaliri air sebesar 101,189 ltr/dtk ke DMA 1,2,4 dan 5 dan Reservoir 2 Betek sebesar 233,339 ltr/dtk ke DMA 3,6 dan 7. Berdasarkan simulasi software WaterCAD V8i di Zona Betek didapatkan hasil tekanan, kecepatan, headloss gradient, dan sisa klorin pada kondisi eksisting dan pengembangan dengan syarat tekanan yang diijinkan 0,5-10 atm, kecepatan yang diijinkan 0,3-6 m/detik, headloss gradient yang diijinkan 0-15 m/km dan sisa klorin yang diijinkan 0,3-0,5 mg/l.
References
Departemen Pekerjaan Umum. 1985. Keputusan Menteri Pekerjaan Umum No: 02/KPTS/ 1985 Tentang Ketentuan Pencegahan dan Penanggulangan Kebakaran pada Bangunan Gedung . Jakarta: Departemen Pekerjaan Umum.
Departemen Pekerjaan Umum. 2000. Keputusan Menteri Pekerjaan Umum No: 10/KPTS/ 2000 Tentang Ketentuan Teknis Pengamanan Terhadap Bahaya Kebakaran pada Bangunan Gedung dan Lingkungan. Jakarta: Departemen Pekerjaan Umum.
F.P.Budiman, R.Haribowo, M. J Ismoyo., “Evaluasi Sistem Distribusi Air Bersih Zona Rumah Pompa Krembangan Kota Surabayaâ€. Jurnal Teknologi dan Rekayasa Sumber Daya Air Vol. 2 No. 1 (2022) p. 144-155.
R.Nuramalia, R.Haribowo, H.Siswoyo. “Evaluasi Sistem Distribusi Air Bersih Di Zona Wendit PDAM Kota Malang Dengan Menggunakan Paket Program WaterCAD V8iâ€. Jurnal Mahasiswa Jurusan Teknik Pengairan. Vol 3. No 2 (2020).
Bentley Methods. 2007. User’s Guide WaterCAD v8i for Windows WATERBUY CT. USA: Bentley Press.
Badan Pusat Statistik. 2015. Pedoman Perhitungan Proyeksi Penduduk dan Angkatan Kerja. Jakarta: Badan Pusar Statistik.
E.W.Diana, M.Sholichin, R.Haribowo.,“Kajian Pengembangan Jaringan Distribusi Air Bersih Pada PDAM Tirta Barito Kota Buntok†Jurnal Teknik Pengairan. 2020. 11(1) pp.8-17.
E.Rohmaningsih, M.Sholichin, R.Haribowo.,“Kajian Pengembangan Sistem Penyediaan Air Bersih Pada Daerah Rawan Air Di Desa Sumbersih Kecamatan Panggungrejo Kabupaten Blitarâ€.Jurnal Teknik Pengairan. Volume 8. Nomor 1. Mei 2017. hlm 48-59.
A.P.Abriani, J.Ismoyo, R.Haribowo.†Aplikasi Software Watercad V8i Untuk Evaluasi dan Pengembangan Sistem Jaringan Distribusi Air Bersih di Desa Rejosari Kecamatan Bantur Kabupaten Malang†. Jurnal Teknologi dan Rekayasa Sumber Daya Air .Vol 1 .No. 1. (2021) . p. 284-297
Badan Standarisasi Nasional. (2000). SNI 03-1735-2000. Jakarta: Badan Standarisasi Nasional